GE Aespire S5 Anesthesia Machine with 7900 Smartvent

The Aespire 7900 combines the exceptional performance of the 7900 SmartVent with advanced patient monitoring technology into an affordable anesthesia delivery solution that’s well-suited for the ambulatory surgery center.

The Aespire 7900 combines the exceptional performance of the 7900 SmartVent with advanced patient monitoring technology into an affordable anesthesia delivery solution that’s well-suited for the ambulatory surgery center.

Clinician-inspired solutions help improve patient care

Clinical inspired Ventilation

You asked for sophisticated ventilation capabilities that help you meet the needs of a broad patient range. The Aespire 7900 satisfies your request with the 7900 SmartVent ventilator. The SmartVent uses a similar gas delivery system that is found in most critical care ventilators, yet has been adapted specifically for anesthesia applications and is easily controlled via our intuitive user interface.
Ideal for spontaneously breathing patients

SIMV and PSVPro modes include an adjustable flow trigger, trigger window, electronic PEEP and an apnea backup mode to simplify the work of caring for your spontaneously breathing patients. Patients with laryngeal mask airways (LMAs) and those that cannot tolerate certain anesthetic agents can benefit from the use of SIMV and PSVPro modes from the use of SIMV and PSVPro modes.

A wide range of ventilation odes expands the clinical capabilities of the Aespire 7900 SmartVent to help meet your patient’s needs:

  • Volume control
  • Pressure Control
  • Synchronized Intermittent Mandatory Ventilation (SIMV) with pressure Support
  • PSVPro(Pressure Support with Apnea backup mode)
  • The pressure Control Mode lets you chose a target pressure and deliver the maximum tidal volume for the desired time and pressure selected.

Features & Specifications

Physical Weight & Dimensions

Physical Weight & Dimensions
  • Height: 134.5 cm/52.9 in
  • Width: 72 cm/28.3 in
  • Depth: 73 cm/28.7 in
  • Weight: Approximately 108 kg/238 lb
Top Shelf
  • Weight limit: 34 kg/75 lb
  • Width: 66 cm/26 in
  • Depth: 40 cm/15.75 in
Work Surface
  • Height: 81.7 cm/32.2 in
  • Size: 2160 cm-2/334 in-2
DIN Rail Side of machine: 34.5 cm/13.6 in
Drawers (internal dimensions)
  • Height: 17.5 cm/6.9 in
  • Width: 33 cm/13 in
  • Depth: 26.5 cm/10.4 in
Absorber Bag Arm (optional)
  • Arm length: 30.5 cm/12 in
  • Bag arm height (adjustable): 87 cm (34.3 i) to 104 cm (40.9 in)

Electrical Specifications

Current Leakage
  • 100/120 V: < 300μA
  • Power input: 100-120 Vac, 50/60 Hz
  • Power cord: Length: 5 m/16.4 ft
  • Rating: 15A @ 120 Vac
Inlet/outlet modules (120 V)
  • System circuit breakers: 15A
  • Outlets (optional): 4 outlets on back, 3-2A, 1-3A individual breakers, optional isolation transformer

Pneumatic Specifications

Auxiliary Common Gas Outlet Connector: ISO 22 mm OD and 15 mm ID
Gas Supply
  • Pipeline input range: 240 kPa to 600 kPa/35 psig to 88 psig
  • Pipeline connections: DISS-male, DISS-female, DIN 13252, AS4059, S90-116 or NIST (ISO 5359). All fittings available for O2, N2O, and Air, and contain pipeline filter and check valve.
  • Cylinder input: Pin indexed in accordance with CGA-V-1 or DIN (nut and gland); contains input filter and check valve
  • Note: Maximum 3 cylinders; two inboard mounted, one outboard mounted.
  • Primary regulator diaphragm minimum burst pressure: 2758 kPa/400 psig
  • Primary regulator nominal output: < 338 kPa/49 psig Pin indexed cylinder connections
  • < 407 kPa/59 psig DIN cylinder connections

Environmental Specifications

System Operation
  • Temperature: 10° to 40°C/50° to 104°F
  • Humidity: 15 to 95% relative humidity (non-condensing) per IEC 68-2-3
  • Altitude: -440 to 3565 m/500 to 800 mmHg
System Storage
  • Temperature: -15° to 50°C/-5° to 122°F
  • Humidity: 10 to 95% relative humidity (including condensing) per IEC 68-2-3
  • Altitude: -440 to 3565 m/500 to 800 mmHg
  • Oxygen cell storage: -15° to 50°C/5° to 122°F; 10 to 95% relative humidity; 500 to 800 mmHg
Electromagnetic Compatibility
  • Immunity: Complies with all requirements of EN 60601-1-2
  • Emissions: CISPR 11 group 1 class B
  • Approvals: UL 2601-1; CSA C22.2 #601.1; EN/IEC 60601-1; CE 0197
Specialty

Area

Reviews

There are no reviews yet.

Be the first to review “GE Aespire S5 Anesthesia Machine with 7900 Smartvent”

Your email address will not be published. Required fields are marked *

Scroll to Top