The GE Aisys CS2 is an anesthesia machine that is a technologically sophisticated class of digital Carestation that manages an intuitive user-interface. It features a movable 15-inch touch ventilator display monitor with a Carescape inspired user-experience. An electronic agent control helps provide the Aisys CS2 exceptional benefits, such as automatic record-keeping of set agent concentration and agent usage calculations.
- Moveable 15” touch ventilator monitor.
- Integrated gas with Carescape respiratory technology.
- Configurable quick picks for FGF settings and O2%.
- Compact breathing system designed for low flow to help provide fast gas kinetics for rapid wash-in and wash-out.
- Digitally controlled vaporizer, ventilator, and gas delivery.
- Responsiveness to changes in patient status is measured in milliseconds.
- Advanced breathing system (ABS) ensures a fast circuit response to assist clinicians with anesthesia delivery.
Features & Specifications
Dimensions
Height: 52.7 in (133.9 cm)
Width: 26.8 in (68 cm)
Depth: 82 in (32.3 cm)
Weight: 419 lbs. (190 kg)
Ventilator Performance
Pressure Range at Inlet: 240 kPa to 700 kPa/35 psig to 102 psig
Peak Gas Flow: 120 L/min + fresh gas flow
Flow Valve Range: 1 to 120 L/min
Flow Compensation Range: 200 mL/min to 15 L/min
Patient Spirometry
Pressure-Volume Loop
Flow-Volume Loop
Pressure-Flow Loop
Airway Pressure and Flow Waveforms
Adjustable Low and High Alarm Limits for Ppeak and MVexp
Detection Through Machine Flow Transducers.
Ventilator Accuracy
Volume Delivery: > 210 mL = better than 7%; ≤ 210 mL = better than 15 mL; 210 mL = better than 9%; ≤ 210 mL = better than 18 mL; < 60 mL = better than 10 mL
Pressure monitoring: ±5% or ±2 cmH2O
Flow Transducer
Type: Variable orifice flow sensor
Dimensions: 22 mm OD and 15 mm ID
Location: Inspiratory outlet and expiratory inlet
Oxygen Sensor
Type: Optional galvanic fuel cell or paramagnetic with Respiratory Module option
Ventilator Screen
Display Size: 38 cm/15 in
Pixel Format: 1024 (H) x 768 (V)
Communication Ports
RS-232C compatible serial interface
Ethernet
Datex-Ohmeda device interface solutions port
USB port
VGA Output
Ventilation Parameters
Tidal Volume Range: 20 to 1500 mL (Volume Control, PCV-VG, SIMV and SIMV PCV-VG modes)
Incremental Settings: 20 to 50 mL (increments of 1 mL); 50 to 100 mL (increments of 5 mL); 100 to 300 mL (increments of 10 mL); 300 to 1000 mL (increments of 25 mL); 1000 to 1500 mL (increments of 50 mL)
Minute Volume Range: Less than 0.1 to 99.9 L/min
Pressure (P) Inspired Range: 5 to 60 cmH2O (increments of 1 cmH2O); 5 to 1500 mL volume delivery
Pressure (P) Max Range: 12 to 100 cmH2O (increments of 1 cmH2O)
Pressure (P) Support Range: Off, 2 to 40 cmH2O (increments of 1 cmH2O)
Rate: 4 to 100 breaths per minute for Volume Control, Pressure Control and PCV-VG; 2 to 60 breaths per minute for SIMV, PSVPro, SIMV PCV-VG; 4 to 60 breaths per minute for CPAP+PSV (increments of 1 breath per minute)
Inspiratory/Expiratory Ratio: 2:1 to 1:8 (increments of 0.5)
Inspiratory Time: Inspiratory time: 0.2 to 5.0 seconds (increments of 0.1 seconds) (SIMV, PSVPro, SIMV PCV-VG and CPAP+PSV)
Trigger Window: 0 to 80% (increments of 5%)
Flow Trigger: 1 to 10 L/min (increments of 0.5 L/min) 0.2 to 1 L/min (increments of 0.2 L/min)
Inspiration Termination Level: 5 to 75% (increments of 5%) – Rise Rate 1-10 (PCV, PCV-VG, SIMV, PSVPro, CPAP+PSV and SIMV PCV-VG)
Inspiratory Pause Range: 0-60%
Anesthetic Agent Delivery
Vaporizer: Aladin2 Cassette – Isoflurane, Desflurane, Sevoflurane, or Enflurane
Number of Active Positions: 1
Total (Enf, Iso, Sev) Capacity: 220 mL
Total (Des) Capacity: 240 mL
When cassette indicator shows empty (Enf, Iso, Sev): 125 mL (95 mL residual volume)
When cassette indicator shows empty (Des): 140 mL (100 mL residual volume) Warranty:
For new products, please refer to the manufacturer's website for details.
This product has been refurbished and tested to the highest quality standards by The PCB Medical. This Limited Warranty offered by PCB Medical covers defects in material or workmanship. This warranty extends to the original purchaser only and is nontransferable. The warranty begins the day the equipment is received. Please inspect your item(s) upon delivery. Any unauthorized service providers working on our equipment within the warranty period will void the warranty!
Our warranty periods are very based on product, a standard 30 day parts warranty is included with all refurbished parts unless stated otherwise on the quote/Invoice. Warranties begin from the documented date of receipt.
Our warranties do not cover any problem that is caused by: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.
Our limited warranties are void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).
PCB Medical will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling warranty statement included with your product and you follow proper return procedure. To request warranty service, you will need to provide: 1. The invoice or other evidence of the date and place of purchase. 2. A description of the problem. 3. Contact our Customer Service Department to receive a Return Authorization Number (RMA#)
Shipping and Returns:
Damaged freight needs to be reported within 24 hours to file a claim. No merchandise may be returned without prior written authorization by PCB Medical.
No NEW merchandise may be returned unless authorization from manufacturer which could result in a restocking fee or no return at all, and customer is responsible for shipping expenses.
Return period for products is thirty (30) days from delivery or otherwise agreed upon.
The PCB Medical will test returned products returned and can impose a customer fee if the customer misrepresents the condition of the product.
CREDIT AND RETURN SHIPPING GUIDELINES
Order cancellations (after 24 hours) and returns are charged a 45% restocking fee. Damaged goods will receive credit dependent on the condition of the product, and customer is responsible for shipping expenses.
No credit will be issued if the item is non-returnable, such as a new product, custom or special order, or in the case that the item is damaged due to improper handling/packaging by the customer.
Shipping Charges: Customers are responsible for making sure items can be delivered into or outside of their facility without issue. For example, can a 53’ foot truck access your building? Failure to accommodate delivery can result in items not being delivered, additional fees, or return of equipment.
Basic Shipping Charge is for dock to dock shipping and/or liftgate service shipping. The items shipping dock to dock and/or liftgate are skidded/palletized items. It doesn’t not include inside delivery.
Residential shipping charge is for customer’s needing delivery in a residential area.
Inside delivery is for customer’s needing their purchase delivered inside the building. The item(s) will be delivered into the lobby only. They are not delivered into rooms/suites, elevators, or stairs.
Customers are responsible for disposing of packing materials.
If you are needing white glove delivery, please contact us directly at INFO@pcbhme.com






Reviews
There are no reviews yet.