CareFusion Alaris PC 8015

The CareFusion Alaris 8015 PC Unit is the core of the Alaris System. It provides a common user interface for programming infusions and monitoring, which helps to reduce complexity at the point of care. The display on the Alaris PC Unit uses color to clearly communicate critical programming, infusion, monitoring, and hospital-defined policy information. The Alaris PC utilizes a wireless network card that provides wireless communication capability between the Alaris System and Alaris Systems Manager. With the combined use of the Alaris PCU System and Alaris, Systems Manager is integrated into a facility’s existing network infrastructure.

The CareFusion Alaris 8015 PC Unit is the core of the Alaris System. It provides a common user interface for programming infusions and monitoring, which helps to reduce complexity at the point of care. The display on the Alaris PC Unit uses color to clearly communicate critical programming, infusion, monitoring, and hospital-defined policy information. The Alaris PC utilizes a wireless network card that provides wireless communication capability between the Alaris System and Alaris Systems Manager. With the combined use of the Alaris PCU System and Alaris, Systems Manager is integrated into a facility’s existing network infrastructure.

Supports Guardrails Suite MX with Guardrails Point-Of-Care software and v9 Operating System software. Alaris PC 8015 POC is the Central module to the Alaris medley system. This central ‘brain’ allows other modules to connect to it. It has a color screen, wireless capabilities, and is user-friendly.

  • Wireless connectivity
  • Powerful analytics
  • Exceptional versatility
  • Increased protection for IV safety

Features & Specifications

Dimensions

Height: 8.8 in (22.4 cm)
Width: 6.9 in (17.5 cm)
Depth: 9 in (22.9 cm)
Weight: 7.2 lbs (3.2 kg)

Other

Battery: Battery run time is a function of the number of modules attached and module activity. With a new, fully charged battery, the system operates as follows before a “BATTERY DISCHARGED” message occurs:

  • 6 Hours: with one Pump module infusing at 25 mL/h
  • 6 Hours: with one Pump module infusing at 25 mL/h and one Auto-ID module
  • 3 Hours: with four Pump modules infusing at 25 mL/h
  • 3 Hours: with four Pump modules infusing at 25 mL/h and one Auto-ID module
  • 4.5 Hours: with one active SpO2 module
  • 6 Hours: with one Syringe module or PCA module infusing at 5 mL/h
  • 3 Hours: with four Syringe modules, or one PCA module and three Syringe modules, infusing at 5 mL/h
  • 4 Hours: with one active EtCO2 module
Communication Data Port: RS-232 with an RJ45 connector
Memory:
  • The System configuration/data set is stored in compact flash memory along with operating software.
  • The events and error logs are stored in the onboard flash memory in the Alaris PC unit and modules. This is a nonvolatile memory and can be held indefinitely or until replaced with new data and not lost when power is turned off or the battery is in a weak/discharged state.
  • Module-specific parameters are stored for 8 hours when the system is turned off. After 8 hours of continuous off-time, or if a module is detached, module-specific trend data (if applicable) and module-specific operating parameters are automatically purged. If a PCA, SpO2 or EtCO2 module is detached and replaced with another PCA, SpO2, or EtCO2 module, its module-specific trend data is purged.
  • Memory will not be lost due to a weak/discharged battery as data is stored on flash memory as noted.
  • Compact flash memory: Stores application software, audio wave files, DataSet, and hex files data for operating system software, all needed to operate the Alaris PC Unit System.
  • On-board flash memory: Contains software needed to initially turn on the Alaris 8105 System. Stores boot software applications, and events, errors and battery logs.

The CareFusion Alaris 8015 PC Unit is the core of the Alaris System. It provides a common user interface for programming infusions and monitoring, which helps to reduce complexity at the point of care. The display on the Alaris PC Unit uses color to clearly communicate critical programming, infusion, monitoring, and hospital-defined policy information. The Alaris PC utilizes a wireless network card that provides wireless communication capability between the Alaris System and Alaris Systems Manager. With the combined use of the Alaris PCU System and Alaris, Systems Manager is integrated into a facility’s existing network infrastructure.

Supports Guardrails Suite MX with Guardrails Point-Of-Care software and v9 Operating System software. Alaris PC 8015 POC is the Central module to the Alaris medley system. This central ‘brain’ allows other modules to connect to it. It has a color screen, wireless capabilities, and is user-friendly.

Wireless connectivity
Powerful analytics
Exceptional versatility
Increased protection for IV safety
Exceptional versatility
A common user interface simplifies IV administration by standardizing pump, syringe and PCA on one platform
Monitoring can be added with the Alaris SpO2 and EtCO2 modules, allowing the clinician to automatically pause PCA infusions if patients fall below target respiratory level
The Alaris Auto-ID module offers a unique IV barcoding solution that attaches directly onto the Alaris System
Increased protection for IV safety
Guardrails Suite MX software is the most comprehensive safety software available
The wirelessly enabled software is available on every device
Provides the right protection for every infusion by double-checking dose and duration, as well as delivery rate, protecting critical infusions like chemotherapy
Powerful analytics
Guardrails software allows you to convert data into meaningful information, so you can quickly identify opportunities for clinical and operational improvement
With Guardrails CQI Reporter, you have the tools to spot subtle trends, measure the effectiveness of your IV formularies and best practices, and continuously optimize patient care Dimensions
Height: 8.8 In (22.4 cm)
Width: 6.9 In (17.5 cm)
Depth: 9 In (22.9 cm)
Weight: 7.2 lbs (3.2 kg)
Battery
Battery run time is a function of the number of modules attached and module activity. With a new, fully charged battery, the system operates as follows before a “BATTERY DISCHARGED” message occurs:
6 Hours: with one Pump module infusing at 25 mL/h
6 Hours: with one Pump module infusing at 25 mL/h and one Auto-ID module
3 Hours: with four Pump modules infusing at 25 mL/h
3 Hours: with four Pump modules infusing at 25 mL/h and one Auto-ID module
4.5 Hours: with one active SpO2 module
6 Hours: with one Syringe module or PCA module infusing at 5 mL/h
3 Hours: with four Syringe modules, or one PCA module and three Syringe modules, infusing at 5 mL/h
4 Hours: with one active EtCO2 module
Communication Data Port
RS-232 with an RJ45 connector
Memory
The System configuration/data set is stored in compact flash memory along with operating software.
The events and error logs are stored in the onboard flash memory in the Alaris PC unit and modules. This is a nonvolatile memory and can be held indefinitely or until replaced with new data and not lost when power is turned off or the battery is in a weak/discharged state.
Module-specific parameters are stored for 8 hours when the system is turned off. After 8 hours of continuous off-time, or if a module is detached, module-specific trend data (if applicable) and module-specific operating parameters are automatically purged. If a PCA, SpO2 or EtCO2 module is detached and replaced with another PCA, SpO2, or EtCO2 module, its module-specific trend data is purged.
Memory will not be lost due to a weak/discharged battery as data is stored on flash memory as noted.
Compact flash memory: Stores application software, audio wave files, DataSet, and hex files data for operating system software, all needed to operate the Alaris PC Unit System.
On-board flash memory: Contains software needed to initially turn on the Alaris 8105 System. Stores boot software application, and events, errors and battery logs. Warranty:

For new products, please refer to the manufacturer’s website for details.
This product has been refurbished and tested to the highest quality standards by The PCB Medical. This Limited Warranty offered by PCB Medical covers defects in material or workmanship. This warranty extends to the original purchaser only and is nontransferable. The warranty begins the day the equipment is received. Please inspect your item(s) upon delivery. Any unauthorized service providers working on our equipment within the warranty period will void the warranty!
Our warranty periods are very based on product, a standard 30 day parts warranty is included with all refurbished parts unless stated otherwise on the quote/Invoice. Warranties begin from the documented date of receipt.
Our warranties do not cover any problem that is caused by: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.
Our limited warranties are void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).
PCB Medical will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling warranty statement included with your product and you follow proper return procedure. To request warranty service, you will need to provide: 1. The invoice or other evidence of the date and place of purchase. 2. A description of the problem. 3. Contact our Customer Service Department to receive a Return Authorization Number (RMA#)
Shipping and Returns:
Damaged freight needs to be reported within 24 hours to file a claim. No merchandise may be returned without prior written authorization by PCB Medical.
No NEW merchandise may be returned unless authorization from manufacturer which could result in a restocking fee or no return at all, and customer is responsible for shipping expenses.
Return period for products is thirty (30) days from delivery or otherwise agreed upon.
The PCB Medical will test returned products returned and can impose a customer fee if the customer misrepresents the condition of the product.
CREDIT AND RETURN SHIPPING GUIDELINES
Order cancellations (after 24 hours) and returns are charged a 45% restocking fee. Damaged goods will receive credit dependent on the condition of the product, and customer is responsible for shipping expenses.
No credit will be issued if the item is non-returnable, such as a new product, custom or special order, or in the case that the item is damaged due to improper handling/packaging by the customer.
Shipping Charges: Customers are responsible for making sure items can be delivered into or outside of their facility without issue. For example, can a 53’ foot truck access your building? Failure to accommodate delivery can result in items not being delivered, additional fees, or return of equipment.
Basic Shipping Charge is for dock to dock shipping and/or liftgate service shipping. The items shipping dock to dock and/or liftgate are skidded/palletized items. It doesn’t not include inside delivery.
Residential shipping charge is for customer’s needing delivery in a residential area.
Inside delivery is for customer’s needing their purchase delivered inside the building. The item(s) will be delivered into the lobby only. They are not delivered into rooms/suites, elevators, or stairs.
Customers are responsible for disposing of packing materials.
If you are needing white glove delivery, please contact us directly at INFO@pcbhme.com

Scroll to Top