The Hospira Plum A+ is a Volumetric Infusion pump system. It was designed to deliver a variety of infusion drugs. The Plum A+ is a cassette-based infusion system with two lines and one output line – allowing for multi-function infusions. it additionally features a fully automatic drug delivery, concurrent flow along with preferred dosing and delivery rates, variable occlusion pressure, and an optional bar code reader. The Hospira Infusion Pump was designed to deliver parental, enteral, and epidural infusion over a wide rate of infusion rates from a variety of fluid types. The Infusion pump can be used on a wide range of patient types from Neonatal, Pediatric, and adult, in a variety of hospital settings, intensive care, operating rooms, emergency, and recovery, along with others.
Features & Specifications
Dimensions
| Height: | 8 in |
|---|---|
| Width: | 8 in |
| Depth: | 6 in |
| Weight: | 9.5 lbs with battery |
Electrical
| Power Requirements: | 1120 V-, 50-60 Hz, 35 VA |
|---|---|
| Fuses: | F1, F2, 250V~, 0.5 A (internal) |
| Power Cord: | Hospital-grade AC cord. 10 ft long, with transparent plug and retainer plate. |
| Battery: | One sealed, lead-acid, rechargeable 6 V battery, internal to device. |
| Battery life: | with a new fully charged battery, the infuser shall operate for a minimum of six hours at 125mL/hr or less, or deliver 500 mL at 126 mL/hr or greater on one line. |
| Recharge: | The battery charges whenever the Plum A+ is connected to AC power. The recharge time is approximately six hours with the device operating at 125 mL/hr on one line. |
Environment
| Operating Temperature: | 5 to 40 degrees C |
|---|---|
| Storage Temperature: | -20 to 60 degrees C |
| 0 – 10,000 feet (0 – 3,000 m) or equivalent pressure | |
| Relative Humidity: | 10 – 90% (40 degrees C Max) |
Delivery Rate Range
| Line A and B: | 0.1 – 99.9 mL/hr (in 0.1mL increments) 100 – 999 mL/hr (in mL iincrements) |
|---|---|
| Concurrent delivery: | 0.5 mL/hr minimum for each line |
| Plu,Set: | 500 mL/hr cumulate (A+B) Maximum |
| KVO: | 1.0 mL/hr or the last primary delivery rate, whichever is less |
Therapies
| Dose Calculation | |
| Loading Dose | |
| Multi-step programming |
PlumSet Capabilities
| Anti free-flow protection | |
| Direct connection for syringe delivery |
The Hospira Plum A+ is a Volumetric Infusion pump system. It was designed to deliver a variety of infusion drugs. The Plum A+ is a cassette-based infusion system with two lines and one output line – allowing for multi-function infusions. it additionally features a fully automatic drug delivery, concurrent flow along with preferred dosing and delivery rates, variable occlusion pressure, and an optional bar code reader. The Hospira Infusion Pump was designed to deliver parental, enteral, and epidural infusion over a wide rate of infusion rates from a variety of fluid types. The Infusion pump can be used on a wide range of patient types from Neonatal, Pediatric, and adult, in a variety of hospital settings, intensive care, operating rooms, emergency, and recovery, along with others.
Security
Confidence that the system is properly programmed comes from the clear, easy-to-read display that provides all of the dosing parameters on a single screen. Mandatory confirmation screens help clinicians to avoid medication errors.
Flexibility
Clinicians can choose from a variety of programming options
Automated piggyback delivery
Automated concurrent delivery
Programmable standby settings
Multistep delivery
Loading dose automation
Programmable delayed starts Dimensions
Height: 8 in
Width: 8 in
Depth: 6 in
Weight: 9.5 lbs with battery
Electrical
Power Requirements: 1120 V-, 50-60 Hz, 35 VA
Fuses: F1, F2, 250V~, 0.5 A (internal)
Power Cord: Hospital-grade AC cord. 10 ft long, with transparent plug and retainer plate.
Battery: One sealed, lead-acid, rechargeable 6 V battery, internal to device.
Battery life: with a new fully charged battery, the infuser shall operate for a minimum of six hours at 125mL/hr or less, or deliver 500 mL at 126 mL/hr or greater on one line.
Recharge: The battery charges whenever the Plum A+ is connected to AC power. The recharge time is approximately six hours with the device operating at 125 mL/hr on one line.
Environment
Operating Temperature: 5 to 40 degrees C
Storage Temperature: -20 to 60 degrees C
0 – 10,000 feet (0 – 3,000 m) or equivalent pressure
Relative Humidity: 10 – 90% (40 degrees C Max)
Delivery Rate Range
Line A and B: 0.1 – 99.9 mL/hr (in 0.1mL increments) 100 – 999 mL/hr (in mL iincrements)
Concurrent delivery: 0.5 mL/hr minimum for each line
Plu,Set: 500 mL/hr cumulate (A+B) Maximum
KVO: 1.0 mL/hr or the last primary delivery rate, whichever is less
Therapies
Dose Calculation
Loading Dose
Multi-step programming
PlumSet Capabilities
Anti free-flow protection
Direct connection for syringe delivery Warranty:
For new products, please refer to the manufacturer’s website for details.
This product has been refurbished and tested to the highest quality standards by The PCB Medical. This Limited Warranty offered by PCB Medical covers defects in material or workmanship. This warranty extends to the original purchaser only and is nontransferable. The warranty begins the day the equipment is received. Please inspect your item(s) upon delivery. Any unauthorized service providers working on our equipment within the warranty period will void the warranty!
Our warranty periods are very based on product, a standard 30 day parts warranty is included with all refurbished parts unless stated otherwise on the quote/Invoice. Warranties begin from the documented date of receipt.
Our warranties do not cover any problem that is caused by: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.
Our limited warranties are void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).
PCB Medical will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling warranty statement included with your product and you follow proper return procedure. To request warranty service, you will need to provide: 1. The invoice or other evidence of the date and place of purchase. 2. A description of the problem. 3. Contact our Customer Service Department to receive a Return Authorization Number (RMA#)
Shipping and Returns:
Damaged freight needs to be reported within 24 hours to file a claim. No merchandise may be returned without prior written authorization by PCB Medical.
No NEW merchandise may be returned unless authorization from manufacturer which could result in a restocking fee or no return at all, and customer is responsible for shipping expenses.
Return period for products is thirty (30) days from delivery or otherwise agreed upon.
The PCB Medical will test returned products returned and can impose a customer fee if the customer misrepresents the condition of the product.
CREDIT AND RETURN SHIPPING GUIDELINES
Order cancellations (after 24 hours) and returns are charged a 45% restocking fee. Damaged goods will receive credit dependent on the condition of the product, and customer is responsible for shipping expenses.
No credit will be issued if the item is non-returnable, such as a new product, custom or special order, or in the case that the item is damaged due to improper handling/packaging by the customer.
Shipping Charges: Customers are responsible for making sure items can be delivered into or outside of their facility without issue. For example, can a 53’ foot truck access your building? Failure to accommodate delivery can result in items not being delivered, additional fees, or return of equipment.
Basic Shipping Charge is for dock to dock shipping and/or liftgate service shipping. The items shipping dock to dock and/or liftgate are skidded/palletized items. It doesn’t not include inside delivery.
Residential shipping charge is for customer’s needing delivery in a residential area.
Inside delivery is for customer’s needing their purchase delivered inside the building. The item(s) will be delivered into the lobby only. They are not delivered into rooms/suites, elevators, or stairs.
Customers are responsible for disposing of packing materials.
If you are needing white glove delivery, please contact us directly at INFO@pcbhme.com






Reviews
There are no reviews yet.